WhatsApp: +8613967773640 Email: gongshun@electric-cn.com
  

DFW-12 cable distribution box

Description


Product details

DFW-12 series cable distribution boxes are designed for outdoor use with a fully sealed structure, and the cabinet protection level reaches IP33. The cable joint bracket is made of stainless steel, and the shell is made of high-quality 2mm stainless steel plate. The interior of the box is divided into a busbar compartment and a cable compartment by the top plate of the cable compartment. The busbar compartment is a sealed compartment surrounded by a 2mm steel plate. The cable joint bracket is located at the top of the busbar compartment, supporting the sleeve used to fix the cable joint. The spacing between cable joints is 180mm. If it is the type with a surge arrester, the arrester is installed at the rear of the cable joint. In addition, short-circuit indicators and live indicators are also installed in the busbar compartment. All live components in the busbar compartment undergo strict silicone rubber insulation treatment. The cable compartment is located at the bottom of the busbar compartment and serves as the channel for the cable to enter and exit. There are cable clamps and grounding terminals inside the compartment.

Model Meaning

Functions and Features
Fully insulated and sealed to ensure personal safety.
Outdoor design, dustproof, moisture-proof, flood-resistant, corrosion-resistant, strong environmental adaptability.
Flexible combination, from two to six incoming and outgoing cables, meeting various wiring requirements. Small size,
compact structure, beautiful appearance, easy installation, and maintenance-free.
Can be equipped with live indicators. Can be equipped with short- circuit indicators.
Can be equipped with surge arresters.

Ambient Condition

Altitude does not exceed 2500m.
Ambient temperature: -45*C to +45°C.
Relative humidity: Daily average not more than 95% , monthly average not more than 90%.
Installation location: Places without fire hazards, explosive dust, chemical corrosive gases, and severe vibrations.
If it exceeds the above conditions, users can negotiate with our company.

Ordering Information (Must be specified when ordering)

1. Main circuit scheme number, purpose, single-line system diagram, arrangement diagram, and layout diagram of the distribution room.
2. Auxiliary circuit wiring diagram, terminal arrangement diagram.
3. Model, specifications, and quantity of electrical components inside the switchgear.
4. Requirements for control, measurement, and protection functions of the switchgear, as well as other requirements for interlocking and automatic devices.
5. If busbar bridge connections are needed between switchgear or incoming cabinets, provide specific requirements such as the rated current of the busbar bridge, span, and height above ground.
6. Specify types and quantities of accessories and spare parts.
7. If the switchgear is used in special environmental conditions, other special requirements should be detailed when ordering.

Technical Parameter
 
Rated Voltage 12kV Joint Point Resistance 40μΩ
Rated Current 630A Conductor Operating Temperature ≤95℃
Rated Frequency 50Hz Partial Discharge ≤10pc/13kV
Rated Thermal Stability Current 20kA/3s Humidity Test 11kV/100h pass
Rated Dynamic Stability Current(Peak) 50kA Applicable Cable Types XLPE
Power Frequency Withstand Voltage 45kA/1min Applicable Cable Cross-Section 25℃~400℃
Lightning Impulse Withstand Voltage 105kV Applicable Ambient Temperature -40℃~+50℃
    Applicable Altitude ≤3000m


 